Vol.4 , No. 1, Publication Date: Feb. 27, 2018, Page: 8-14
[1] | Ligeng Shao, School of Electrical and Information Engineering, Dalian Jiaotong University, Dalian, China. |
[2] | Yanming Wu, School of Electrical and Information Engineering, Dalian Jiaotong University, Dalian, China. |
The control method of inverter for low power single-phase motor mainly uses pulse width modulation technology. Based upon the traditional natural sampling method, the tangent sampling method and the secant sampling method, the switching time point calculation formulae are derived for the double tangent sampling method. Compared the switching time with above three methods and analyzing the error precision, the SPWM wave generated by the double tangent sampling method are closest to the wave generated by the natural sampling method. The double tangent sampling method can improve the accuracy of SPWM wave. The harmonic analysis indicates that the SPWM wave obtained by the double tangent sampling method has greater fundamental component, and its low order harmonic components are closer to the natural sampling method compared with the SPWM wave obtained by the secant sampling method. The double tangent method realizes easily in digital systems. It is feasible to obtain an ideal SPWM wave by the double tangent method.
Keywords
Sinusoidal Pulse Width Modulation (SPWM), Tangent Sampling Method, Secant Sampling Method, Double Tangent Sampling Method
Reference
[01] | H. F. Xiao, K. Lan and L. Zhang, A quasi-unipolar SPWM full-bridge transformerless PV grid-connected inverter with constant common-mode voltage, IEEE Transactions on Power Electronics, 30 (6): 3122-3132, 2015. |
[02] | M. Lakka, E. Koutroulis and A. Dollas, Development of an FPGA-based SPWM generator for high switching frequency DC/AC inverters, IEEE Transactions on Power Electronics, 29 (1): 356-365, 2014. |
[03] | I. Colak and E. Kabalci, Developing a novel sinusoidal pulse width modulation (SPWM) technique to eliminate side band harmonics, International Journal of Electrical Power & Energy Systems, 44 (1): 861-871, 2013. |
[04] | M. M. Renge and H. M. Suryawanshi, Multilevel inverter to reduce common mode voltage in AC motor drives using SPWM technique, Journal of Power Electronics, 11 (1): 21-27, 2011. |
[05] | K. Jain and P. Chaturvedi, Matlab-based simulation & analysis of three-level SPWM inverter, International Journal of Soft Computing and Engineering, 2 (1): 56-59, 2012. |
[06] | T. H. Li, S. H. Chung and K. M. Chan, An active modulation technique for single-phase grid-connected CSI, IEEE Transactions on Power Electronics, 22 (4): 1373-1382, 2007. |
[07] | J. Huang and H. Shi, Reducing the common-mode voltage through carrier peak position modulation in an SPWM three-phase inverter, IEEE Transactions on Power Electronics, 29 (9): 4490-4495, 2014. |
[08] | I. Colak and E. Kabalci, Developing a novel sinusoidal pulse width modulation (SPWM) technique to eliminate side band harmonics, Electrical Power and Energy Systems, 44 (1): 861–871, 2013. |
[09] | Z. X. Zhang, H. Ma and X. N. He, Study on novel SPWM sampling methods, Journal of Zhejiang University: Engineering Science, 39 (4): 588-594, 2005. |
[10] | R. Nagarajan and M. Saravanan, Performance analysis of a novel reduced switch cascaded multilevel inverter, Journal of Power Electronics, 14 (1): 48-60, 2014. |
[11] | C. F. Zheng, B. Zhang and D. Y. Qiu, Digital natural sampling SPWM based on inverse operator method, in Proc. IEEE APESC, 792-797, 2007. |
[12] | A. R. Beig, G. Narayanan and V. T. Ranganathan, Modified SVPWM algorithm for three level VSI with synchronized and symmetrical waveforms, IEEE Transactions on Industrial Electronics, 54 (1): 486-494, 2007. |
[13] | B. Ismail, S. Taib, A. R. M. Saad, M. Isa and C. M. Hadzer, Development of a single phase SPWM microcontroller-based inverter, in Proc. IEEE PEC, 437-440, 2006. |
[14] | X. D. Liu and T. Xu, Precision analysis of SPWM switching time point, Electric Power Automation Equipment, 30 (12): 55-59, 2010. |