Abstract
 

In order to study the external insulation system of high-rise building in severe cold regions, the author classified the external insulation wall by the difference of materials and technics, made a discussion especially on the EPS plates thin plaster system, the adhesive polystyrene thermal insulation mortar system, and the spot spraying of rigid polyurethane composite powder polystyrene particles such as exterior insulation system which were widely used at present, analyzed the combustion characteristics of different insulation materials and showed the exterior insulation system of high-rise building the key elements of security. The result show that the external insulation system of high-rise building of fire-retardant lies in materials and technics.


Keywords
 

High-Rise Buildings, Exterior Insulation, Fire-Retardant, Cold Regions


Reference
 
[01]    

A Berge. Novel Thermal Insulation in Future Building and District Heating Applications - Hygrothermal Measurements and Analysis, Chalmers University of Technology, 2013.

[02]    

V Marincioni, H Altamirano-Medina. Effect of orientation on the hygrothermal behaviour of a capillary active internal wall insulation system, Nordic Symposium of Building Physics, 2014.

[03]    

Chun Lv. Status and development trend of energy-saving wall materials in cold areas [J], Advanced Materials Research Vols. 150-151, Part 1, 2011: 630-633.

[04]    

G Cevc, G Blume. Thermal performance of exterior wall external insulation system with foamed glass [J], New Building Materials, 2011, 1514 (2): 191-205.

[05]    

CY Song, P Zhang, FU etc, Exploitation and Application of ZL Adhesive Polystyrene Attached to XPS Board in Exterior Wall External Insulation System [J], Construction Technology, 2006, 70 (1): 71-73.

[06]    

The Ministry of Construction: Exterior Insulation Polyurethane Foam Engineering Guide, In Chinese (May 19, 2007).

[07]    

China National Chemical Engineering Corporation: Rigid Polyurethane Foam construction technology standards, In Chinese.

[08]    

National construction industry standards: Expanded polystyrene board exterior wall insulation system, In Chinese (JG149-2003): 2-4.

[09]    

Zhenli Huang: Adhesive Polystyrene Exterior Insulation System. In Chinese (JG158-2004): 4-6.

[10]    

Lv Chun, Study on Fire Protection of High-rise Building Exterior Insulation System in Cold Areas [J], Low Temperature Construction Technology, 2013 (10): 126-129.

[11]    

Chun Lv, Application of new composite insulation walls in northern cold area s [J], New building Materials, 2011 (1): 81-83.





 